Failing function codes, failing items and symbolic FRUsESCALA Power7 REFERENCE 86 A1 53FF 05
CAUTION:Removing components from the upper positions in the rack cabinet improves rack stability duringrelocation. Follow these general guidelines whe
Failing function code 637The problem is a dual channel PCI-2 ultra2 SCSI adapter.The FRU part number is 03N3606.If you need additional information for
Failing function code 63BThe problem is a 9.1 GB 10,000 rpm, 80-pin SCSI disk drive.The FRU part number is 07N4853.If you need additional information
Failing function code 640The 9.1 GB Ultra SCSI disk drive (80-pin) might be failing.Use the following table to determine the part number for the field
If you need additional information for failing part numbers, location codes, or removal and replacementprocedures, see Part locations and location cod
If you need additional information for failing part numbers, location codes, or removal and replacementprocedures, see Part locations and location cod
CCIN or FFC Type and model Part number Description Location code653 Any 59H6923 18.2 GB ultra-SCSI16-bit disk driveIf you need additional information
If you need additional information for failing part numbers, location codes, or removal and replacementprocedures, see Part locations and location cod
CCIN or FFC Type and model Part number Description Location code667 Any 01K7396 PCI 3-channel ultra2SCSI RAID adapterIf you need additional informatio
Failing function code 66DThe PCI 4-channel Ultra3 SCSI RAID adapter might be failing.Use the following table to determine the part number for the fiel
Failing function code 673The 18.2 GB differential SCSI disk drive might be failing.Use the following table to determine the part number for the field
(L003)orAll lasers are certified in the U.S. to conform to the requirements of DHHS 21 CFR Subchapter J for class1 laser products. Outside the U.S., t
If you need additional information for failing part numbers, location codes, or removal and replacementprocedures, see Part locations and location cod
If you need additional information for failing part numbers, location codes, or removal and replacementprocedures, see Part locations and location cod
684 Any 93H6563 Enhanced remoteasynchronous node,16-Port RS-422684 Any 93H7091 Power supply, remoteasync nodeIf you need additional information for fa
Failing function code 689The 4.5 GB 16-bit Ultra SCSI SE disk drive might be failing.Use the following table to determine the part number for the fiel
If you need additional information for failing part numbers, location codes, or removal and replacementprocedures, see Part locations and location cod
If you need additional information for failing part numbers, location codes, or removal and replacementprocedures, see Part locations and location cod
CCIN or FFC Type and model Part number Description Location code69B Any 21P4106 64-bit/66 MHz PCIATM MMF adapterIf you need additional information for
If you need additional information for failing part numbers, location codes, or removal and replacementprocedures, see Part locations and location cod
Failing function code 703The disk drive might be failing.Use the following table to determine the part number for the field replaceable unit (FRU).CCI
Failing function code 706The disk drive might be failing.Use the following table to determine the part number for the field replaceable unit (FRU).CCI
CAUTION:Data processing environments can contain equipment transmitting on system links with laser modulesthat operate at greater than Class 1 power l
CCIN or FFC Type and model Part number Description Location code711 Any Unknown adapterIf you need additional information for failing part numbers, lo
Failing function code 722The disk drive might be failing.Use the following table to determine the part number for the field replaceable unit (FRU).CCI
725 Any 96G2150 P70 display, 17-inch,southern hemisphere725 Any 21L4570 P72 display, 17-inch,northern (white)725 Any 21L4571 P72 display, 17-inch,nort
Failing function code 727The async device might be failing.Use the following table to determine the part number for the field replaceable unit (FRU).C
If you need additional information for failing part numbers, location codes, or removal and replacementprocedures, see Part locations and location cod
CCIN or FFC Type and model Part number Description Location code742 Any 11H8128 T2 PCI EthernetadapterIf you need additional information for failing p
If you need additional information for failing part numbers, location codes, or removal and replacementprocedures, see Part locations and location cod
CCIN or FFC Type and model Part number Description Location code751 Any 08L1319 SCSI 32-bit SE F/WRAID adapter751 Any 06H6036 SCSI RAID cable (1.0m)75
If you need additional information for failing part numbers, location codes, or removal and replacementprocedures, see Part locations and location cod
CCIN or FFC Type and model Part number Description Location code774 Any 27H1677 9.1 GB external SCSIDE disk driveIf you need additional information fo
Failing function codes, failing items, and symbolic FRUsFailing function codes (FFCs), failing items, and symbolic field replaceable units (FRUs) prov
Failing function code 778The graphics adapter might be failing.Use the following table to determine the part number for the field replaceable unit (FR
Failing function code 781The coprocessor multiport adapter might be failing.Use the following table to determine the part number for the field replace
If you need additional information for failing part numbers, location codes, or removal and replacementprocedures, see Part locations and location cod
788 Any 07L9009 Ultimedia videocapture adapterIf you need additional information for failing part numbers, location codes, or removal and replacementp
Failing function code 790The multibus integrated Ethernet adapter might be failing.Use the following table to determine the part number for the field
Failing function code 793The 9.1 GB 16-bit SE disk drive assembly might be failing.Use the following table to determine the part number for the field
CCIN or FFC Type and model Part number Description Location code7C0 Any 03N6902 Interface problembetween processorand system. Replacethe system backpl
Failing function code 807The SCSI device enclosure might be failing.Use the following table to determine the part number for the field replaceable uni
Failing function code 812The adapter might be failing.Use the following table to determine the part number for the field replaceable unit (FRU).CCIN o
CCIN or FFC Type and model Part number Description Location code816 Any Operator panel logicproblemNote: For type,model, and FRUinformation, see FFC22
Failing function code 152A power supply is the problem.See FFC 153.If you need additional information for failing part numbers, location codes, or rem
821 Any Standard keyboardadapter problem.Note: For type,model, and FRUinformation, see FFC221.If you need additional information for failing part numb
825 Any 11K0571 NIO backplane, 9076and POWER3 SMPhigh nodeIf you need additional information for failing part numbers, location codes, or removal and
Any Standard disketteadapter problem.Note: For type,model, and FRUinformation, see FFC221.If you need additional information for failing part numbers,
If you need additional information for failing part numbers, location codes, or removal and replacementprocedures, see Part locations and location cod
Failing function code 844The SCSI subsystem controller might be failing.Use the following table to determine the part number for the field replaceable
868 Any Integrated SCSI I/Ocontroller problem.Note: For type,model, and FRUinformation, see FFC221.If you need additional information for failing part
If you need additional information for failing part numbers, location codes, or removal and replacementprocedures, see Part locations and location cod
Failing function code 900The graphics adapter might be failing.Use the following table to determine the part number for the field replaceable unit (FR
Failing function code 904The parallel device might be failing.Use the following table to determine the part number for the field replaceable unit (FRU
912 Any 86F0125 Differential frameelectronicsAttention: CheckRETAIN for frameelectronicsavailability. Replacethe complete driveassembly wheneverpossib
Failing function code 166The problem is with a fan assembly.Use the following table to determine the part number for the field replaceable unit (FRU).
If you need additional information for failing part numbers, location codes, or removal and replacementprocedures, see Part locations and location cod
CCIN or FFC Type and model Part number Description Location code921 Any 1392090 101-key keyboard921 Any 1394609 101-key keyboardIf you need additional
If you need additional information for failing part numbers, location codes, or removal and replacementprocedures, see Part locations and location cod
Failing function code 930The keyboard might be failing.Use the following table to determine the part number for the field replaceable unit (FRU).CCIN
Any Serial HIPPI PCIadapterNote:1. Use the numberprinted above thebar code to orderthis part.2. The FRU partnumber of thewrap plug that isused for thi
Failing function code 951The 670 MB SCSI disk drive might be failing.Use the following table to determine the part number for the field replaceable un
953 Any 93X0961 320 MB SCSI diskdriveNote: Replace thecomplete drivewhenever possible.Replace the logic cardonly when the dataon the disk must besaved
Failing function code 955The 857 MB SCSI disk drive might be failing.Use the following table to determine the part number for the field replaceable un
960 Any 52G0061 1.37 GB SCSI diskdrive assemblyNote: Logic cardstocking is limited;special ordering isrequired. CheckRETAIN for logiccard availability
963 Any A machine type 3163device is attached.Use devicedocumentation.If you need additional information for failing part numbers, location codes, or
186 Any 53F2662 Co-ProcessorMultiport adapterModel 2 memorymodule (1 MB)Un-P1-CxIf you need additional information for failing part numbers, location
CCIN or FFC Type and model Part number Description Location code968 Any 55F9902 1 GB SCSI SE diskdriveNote: Check RETAINfor frame logic cardavailabili
If you need additional information for failing part numbers, location codes, or removal and replacementprocedures, see Part locations and location cod
If you need additional information for failing part numbers, location codes, or removal and replacementprocedures, see Part locations and location cod
CCIN or FFC Type and model Part number Description Location code984 Any 45G9467 1 GB 8-bit disk driveIf you need additional information for failing pa
CCIN or FFC Type and model Part number Description Location code990 Any 86F0118 2.0 GB SCSI-2 SE diskdriveIf you need additional information for faili
Failing function code 994The 5 GB or 10 GB 8 mm internal tape drive might be failing.Use the following table to determine the part number for the fiel
If you need additional information for failing part numbers, location codes, or removal and replacementprocedures, see Part locations and location cod
If you need additional information for failing part numbers, location codes, or removal and replacementprocedures, see Part locations and location cod
Failing function code B69The coprocessor multiport adapter might be failing.Use the following table to determine the part number for the field replace
If you need additional information for failing part numbers, location codes, or removal and replacementprocedures, see Part locations and location cod
Failing function code 199The problem is with an internal disk unit backplane.See FFC 2667.If you need additional information for failing part numbers,
B82 Any 71F0162 Coprocessormultiport V.35 cableIf you need additional information for failing part numbers, location codes, or removal and replacement
B88 Any Generic SCSI I/OcontrollerNote:1. If the failing FRUfor this FFC isPCI(x), where x isthe PCI busnumber, 0, 1, andso forth, see FFC221.2. Use t
If you need additional information for failing part numbers, location codes, or removal and replacementprocedures, see Part locations and location cod
If you need additional information for failing part numbers, location codes, or removal and replacementprocedures, see Part locations and location cod
CCIN or FFC Type and model Part number Description Location codeC35 Any 65G4887 VOO cardIf you need additional information for failing part numbers, l
CCIN or FFC Type and model Part number Description Location codeC46 Any 65G4890 16 MB VRAMmemory moduleIf you need additional information for failing
Failing function code C95The 4-port selectable interface board might be failing.Use the following table to determine the part number for the field rep
Failing function code C98The cable might be failing.Use the following table to determine the part number for the field replaceable unit (FRU).CCIN or
CCIN or FFC Type and model Part number Description Location codeD01 Any See System parts. Generic L2 cacheproblem. Replace theprocessor card.If you ne
D46 Any 60G1063 Token-ring RJ-45 STPcable, 3 m (10 ft)Note: This cable isnot used with thehigh-speed token-ringPCI adapter.D46 Any 93H8894 RJ-45 to 9-
Failing function code 240The problem is a token-ring network problem.Use the following table to determine the part number for the field replaceable un
D57 Any 07L9822 8-Port multiportinterface cable ISAasync adapterIf you need additional information for failing part numbers, location codes, or remova
Failing function code D67The memory module might be failing.Use the following table to determine the part number for the field replaceable unit (FRU).
If you need additional information for failing part numbers, location codes, or removal and replacementprocedures, see Part locations and location cod
D74 Any System memory. Seethe system unitservice information.If you need additional information for failing part numbers, location codes, or removal a
Failing function code D78The memory module might be failing.Use the following table to determine the part number for the field replaceable unit (FRU).
If you need additional information for failing part numbers, location codes, or removal and replacementprocedures, see Part locations and location cod
If you need additional information for failing part numbers, location codes, or removal and replacementprocedures, see Part locations and location cod
D93 Any See System parts. 32 MB, parity, 70 nsecmemory moduleIf you need additional information for failing part numbers, location codes, or removal a
Failing function code E10The riser card might be failing.Use the following table to determine the part number for the field replaceable unit (FRU).CCI
Failing function code E13The memory module might be failing.Use the following table to determine the part number for the field replaceable unit (FRU).
Failing function code 2503A SAS RAID enablement card might be failing.Replace the SAS RAID enablement card.If you need additional information for fail
If you need additional information for failing part numbers, location codes, or removal and replacementprocedures, see Part locations and location cod
If you need additional information for failing part numbers, location codes, or removal and replacementprocedures, see Part locations and location cod
If you need additional information for failing part numbers, location codes, or removal and replacementprocedures, see Part locations and location cod
Failing function code E3AThe cache battery might be failing.Use the following table to determine the part number for the field replaceable unit (FRU).
Failing function code XXXXThe 4-digit portion of the service request number (SRN) indicates the failing function code to service.Use the 4-digit porti
FI00056FI00056 indicates that any optical bus cable or a missing optical bus wrap connector is the failing item.For cable FRU part numbers, see Planni
FI00090FI00090 indicates that the removable media device for an alternate IPL is the failing item.Determine the device that is failing by performing t
FI00098FI00098 indicates that the load-source disk device is the failing item.Complete the following steps:1. Determine the disk unit 1 type number. I
FI00130FI00130 indicates that the Licensed Internal Code for one of the IOPs or IOAs is the failing item.Determine the IOP or IOA type and location:1.
FI00200FI00200 indicates that the ac module or the removable power cable is the failing item.FI00204FI00204 indicates that the bus cable between the s
Failing function code 2512A SCSI RAID adapter might be failing.Use the following table to determine the part number for the field replaceable unit (FR
FI00240FI00240 is not supported on these models. Continue with the next FRU in the list.FI00244FI00244 is not supported on these models. Continue with
FI00315FI00315 indicates that the installation time life of the battery power unit has been exceeded.Check any attached units that have battery power
FI00580FI00580 indicates that any storage device might be the failing item.The address of the failing storage device cannot be determined.Note the dev
FI00606FI00606 indicates that the storage media is the failing item. Replace the storage media.FI00607FI00607 indicates that a selector light pen atta
Note the cable type, and see Planning for cables to determine the FRU part number to replace.FI00626FI00626 indicates that the modem on the failing po
FI00705FI00705 indicates that the remote data circuit-terminating equipment (DCE) is the failing item.Report this problem to the operator of the remot
FI00717FI00717 indicates that the EIA-232/V.24 non-enhanced cable is the failing item.Check the communications cable for the part number.FI00718FI0071
FI00725FI00725 indicates that the Ethernet IOA card is the failing item.Use the IOA type to determine the part. Note the IOA type and see Managing PCI
Note the cable type, and see Planning for cables to determine the FRU part number to replace.FI00742FI00742 indicates that the communications coupler
FI00851FI00851 indicates that the I/O device attached to the tape IOP is the failing item.Use the service information of the I/O device to continue an
CCIN or FFC Type and model Part number Description Location code2515 Any 44V3296 PCI-X DDR ExternalDual - x4 Port SASadapterUn-P1-CxIf you need additi
FI00872FI00872 indicates that the interface is the failing item.Complete the following:v Internal device: See FI01140.v External device: See symbolic
FI01040FI01040 indicates that you have an OptiConnect system, and the error is on an iSeries or System i®serverthat is connected to it.FI01101FI01101
Complete the following steps:1. Find the IOP address. See the System reference code format description.2. To determine the location of the I/O process
4. Replace the IOAs, cards, cables, and devices that are attached to the IOP, one at a time, until you havecorrected the problem.FI01119FI01119 indica
v Yes: Verify that there is no obvious problem with power to the device. If you suspect a powerproblem with the device, go to the service information
ACMODULYour server lost power. This procedure will help you determine the source of the power loss conditionthat brought you here.If you need addition
8202-E4B, 8202-E4C,8202-E4D, 8205-E6B,8205-E6C, 8205-E6D,8231-E2B, 8231-E1C,8231-E1D, 8231-E2C,8231-E2DSee System parts. Power supply 1 Un-E18202-E4B,
ADJ_PHYThis symbolic FRU displays the physical location code of the previous failing item in the failing item list.No service action is required for t
7620 8231-E2B, 8231-E1C,8231-E1D, 8231-E2C,8231-E2DSee System parts. Cooling fan fault Un-A27630 8231-E2B, 8231-E1C,8231-E1D, 8231-E2C,8231-E2DSee Sys
7611 8408-E8D, 9109-RMD,9117-MMB,9117-MMC,9117-MMD,9179-MHB,9179-MHC,9179-MHDSee System parts. Cooling fan missing Un-A17620 8408-E8D, 9109-RMD,9117-M
Failing function code 2519A PCI-X DDR RAID adapter might be failing.Use the following table to determine the part number for the field replaceable uni
7651 8408-E8D, 9109-RMD,9117-MMB,9117-MMC,9117-MMD,9179-MHB,9179-MHC,9179-MHDSee System parts. Cooling fan missing Un-A57600 5802, 5877 See System par
AJGFN00Licensed Internal Code is the failing item. Look for PTFs associated with the reference code and have thecustomer apply them.AJGJ601Licensed In
Table 1. IXS reference codes and instructionsReference code Instructions1xxx-8910 Check the system error light (amber exclamation point)on the IXS pan
If you need additional information for failing part numbers, location codes, or removal and replacementprocedures, see Part locations and location cod
v If the air being drawn into the unit is above the specified range, either move the unit to a place wherethe air is within range, or take steps to re
AS4NTDDThe Windows server application processor device driver might be causing the problem.Contact your next level of support for assistance.AUXCBLRep
b. If no location information is available for either the device or the I/O adapter, find the address ofthe device or I/O adapter (see the System refe
BPCOne of the BPCs failed to reach standby.Use the following table to perform the appropriate action for the SRC that occurred.SRC Replace this FRU Lo
v No: Complete the following steps:a. Determine the location of the cards in the group using the DSA. Record the DSA (word 7 of thereference code) fro
If you need additional information for failing part numbers, location codes, or removal and replacementprocedures, see Part locations and location cod
If you need additional information for failing part numbers, location codes, or removal and replacementprocedures, see Part locations and location cod
5796, 7314-G30 See System parts. I/O backplane, PCIbridge set 1Un-P1, Un-P1-C1,Un-P1-C2, Un-P1-C3If you need additional information for failing part n
CCIN or FFC Type and model Part number Description Location code8408-E8D, 9109-RMD,9117-MMB,9117-MMC,9117-MMD,9179-MHB,9179-MHC,9179-MHDSee System par
v Yes: The problem is in the FRU with the embedded adapter. Continue with the next step andreplace that FRU.v No: The problem might be intermittent. C
CABLEHThere might be a problem with the cabling between the system controllers and the BPHs.Attention:v Before replacing any cables, ensure that the c
SRC Action Locations information1xxx1D04 Replace the cables between the frontlight strip and the service processors.This ends the procedure.Part locat
2. Use Table 2 below to determine the service action. If more than one location code is listed in the tablefor the cache battery pack, and the locatio
Table 2. Cache battery service information (continued)Type and model Part number Description Location codeReplacementprocedure8202-E4C, 8202-E4D,8205-
Table 2. Cache battery service information (continued)Type and model Part number Description Location codeReplacementprocedure8231-E2B Using the typen
Table 3. Determining the cache battery location (continued)Type and model PCI bus number (decimal) Location code8231-E1C, 8231-E1D, 8231-E2C,8231-E2D1
If you need additional information for failing part numbers, location codes, or removal and replacementprocedures, see Part locations and location cod
Any 97P3960 PCI-X dual channelU320 SCSI RAIDadapter orenablement card.Note:1. Use the locationcode to identify ifthe failing FRU isa RAIDenablement ca
1xxx1D15 The I/O hub card at Un-Pm-C39 inthe book specified by the locationcode reported with the error.1xxx5000 The system controller at Un-P1-C21xxx
5796, 7314-G30 42R4491 Power supply Un-ExFor all other units,– SPCN cables– Power distribution cardThis ends the procedure.2. Is the reference code 1x
8202-E4B, 8202-E4C,8202-E4D, 8205-E6B,8205-E6C, 8205-E6DSee System parts. SPCN port tobackplane cable8202-E4B, 8202-E4C,8202-E4D, 8205-E6B,8205-E6C, 8
11. If your system produced SRC 1xxx9138, you have a faulty location code or vital product data.Contact your next level of support. If your system pro
v No: Contact your next level of support. This ends the procedure.v Yes: This ends the procedure.CBLCONTThis symbolic FRU is used to show additional l
5. Is there a USB interface between the IOA and the device?v No: Continue with the next step.v Yes: Complete the following steps:a. Verify that the US
CLRNVRMA problem might exist with the service processor nonvolatile random access memory (NVRAM).Complete the following steps:1. Is your system manage
8231-E2B, 8231-E1C,8231-E1D, 8231-E2C,8231-E2DSee System parts. Storage backplane Un-P38233-E8B, 8236-E8C See System parts. Media backplane Un-P28408-
CRYPTLPCryptographic adapter Licensed Internal Code problem.The Licensed Internal Code for the cryptographic adapter does not ship with the system.For
Vary off the line. Use the CHGLINETH command to reduce the MAXFRAME value. Then vary the lineback on.CTPNADRThe ADPTADR value in CRTLINETH command is
2524 Any 97P6513 Missing optionsresolution forintegrated PCI-X dualchannel U320 SCSIadapter.Note: Use thelocation code toidentify the failingFRU. If t
If you need additional information for failing part numbers, location codes, or removal and replacementprocedures, see Part locations and location cod
2BBE 8408-E8D, 9109-RMD,9117-MMB,9117-MMC,9117-MMD,9179-MHB,9179-MHC,9179-MHDSee System parts. Device backplane Un-P2-C98. Use the following table to
DEVICEThe addressed storage device is the failing item.Complete the following.1. Is the device location information available in the service action lo
Figure 2. Locations of DIMM 0, DIMM 1, DIMM 2, and DIMM 3 on 2892 Integrated xSeries Server (IXS)card.DIMM 1Use this topic to view the locations of DI
Figure 2. Locations of DIMM 0, DIMM 1, DIMM 2, and DIMM 3 on 2892 Integrated xSeries Server (IXS)card.DIMM2_3Use this topic to view the locations of D
DIMM0_1Use this topic to view the locations of DIMM 0, DIMM 1, DIMM 2, and DIMM 3 on 2892 IntegratedxSeries Server (IXS) card.The first or second DIMM
v If the SRC that sent you here is 506x7631 or 506x7634, replace the 5786, 5787, 7031-D24, or 7031-T24 fanlocated in Un-A3. See the table below to fin
5886 39R6547 Power supply(internal fan)Un-E25887 See System parts. Power supply(internal fan)Un-E15887 See System parts. Power supply(internal fan)Un-
v If the SRC that sent you here is 50ADxxxx or you are working with an attached 5724 expansion unit,this failing item is not applicable. Continue with
8202-E4B, 8202-E4C,8202-E4D, 8205-E6B,8205-E6C, 8205-E6D,8231-E2B, 8231-E1C,8231-E1D, 8231-E2C,8231-E2D, 8233-E8B,8236-E8C21F9345 Two-port adaptercabl
Failing function code 2527The SCSI RAID adapter might be failing.Use the following table to determine the part number for the field replaceable unit (
v Yes: For specific 358x attachment cable information, refer to the specific device and model servicedocumentation, or contact your next level of supp
v All cables for the 9427 tape library must include an interposer (part 05H3834) on the device end ofthe cable.v All cables for the 3996 and 399F atta
CCIN or FFC Type and model Part number Description Location code2787 80P6417 Fibre Channel IOA(for disk driveattachment only)Un-Px-Cy280D 03N5014 4 Gb
b. If the resource is an I/O processor, use "Resources associated with IOP" to find and display detailfor the Fibre Channel I/O adapter. If
11. Ask the customer whether the Fibre Channel IOA will attach devices now or whether the FibreChannel IOA is to be used at a later time.Is the Fibre
If you need additional information for failing part numbers, location codes, or removal and replacementprocedures, see Part locations and location cod
Finding the failing 12X adapter by using AIX or Linux1. Determine on which 12X loop the failing adapter is located. Refer to Converting the loop numbe
CCIN or FFC Type and model Part number Description Location code2BBD 9117-MMB,9117-MMC,9117-MMD,9179-MHB,9179-MHC,9179-MHDSee System parts. Midplane U
2. If the problem persists after replacing the CD, replace the USB CDROM drive.3. Replace the USB adapter to which the drive is attached. Use the foll
28EF 8408-E8D, 9109-RMD,9117-MMB,9117-MMC,9117-MMD,9179-MHB,9179-MHC,9179-MHD80P2994 2 Port USB PCIadapterUn-P2-CxThis ends the procedure.FWCONSThe co
252B Any 39M3417 PCI-X DDR dualchannel ultra320 SCSIadapter (2 way)252B Any 39M3419 PCI-X DDR dualchannel ultra320 SCSIadapter (4 way)If you need addi
FWENETThis symbolic can help determine a problem with an Ethernet adapter.Complete the following.1. Verify that the MAC address is properly programmed
FWIDE1The media or device might be failing.Complete the following steps:1. Replace the media in the device specified by the location code.2. Replace t
1. Contact your network administrator to verify that the network addresses on the server and gatewayare correct.2. Use the System Management Services
FWMBOOTLook here for information about FWMBOOT symbolic FRU.This checkpoint appears on the operator panel when partition firmware has entered the boot
If you need additional information for failing part numbers, location codes, or removal and replacementprocedures, see Part locations and location cod
3) Restart the system.c. If the problem persists, boot the operating system and verify the SCSI bus IDs of the SCSIcontrollers, and correct if necessa
FWPCI2Look here for information about FWPCI2 symbolic FRU.If you receive FWPCI2 symbolic FRU perform the following procedure.1. If the location code i
If you need additional information for failing part numbers, location codes, or removal and replacementprocedures, see Part locations and location cod
8202-E4B, 8202-E4C,8202-E4D, 8205-E6B,8205-E6C, 8205-E6Dwith failing slot onthe PCI riser cardfeature (if installed)See System parts. PCI riser card U
8202-E4B, 8202-E4C,8202-E4D, 8205-E6B,8205-E6C, 8205-E6Dwith failing slot onthe PCI riser cardfeature (if installed)See System parts. PCI riser card U
253 Any The problem is in themultiprotocol cable,EIA-422A, which isprovided by thecustomer.Un-P1-Cx-TyIf you need additional information for failing p
8202-E4B, 8202-E4C,8202-E4D, 8205-E6B,8205-E6C, 8205-E6Dwith failing slot onthe PCI riser cardfeature (if installed)See System parts. PCI riser card U
This ends the procedure.FWRIPLThe FWRIPL procedures can help if a system or a partition will not boot.If a supported adapter is installed, perform the
The location code information is required to identify the ID of SCSI device failures as well as to indicatethe location of the controller to which the
1. The partition firmware is waiting for a virtual terminal to be opened on the management console.Open a virtual terminal.2. If a virtual terminal is
HEAThe failing component is the Host Ethernet Adapter (HEA).If you need additional information for failing part numbers, location codes, or removal an
Note: If you replace all of the FRUs in the FRU list, but the problem still exists, contact your next level ofsupport. You might be directed to replac
v Yes: Service this network adapter error. This ends the procedure.3. Verify that each peer management console with a missing connection is powered on
HSL2This is an HSL2/RIO-G copper HSL/RIO cable at both ends.Diagnostic code cannot determine the length of the cable. Go to HSL_LNK and follow the app
This ends the procedure.HSL2_25This is an HSL2/RIO-G copper HSL/RIO cable at both ends.The 25 value indicates that the cable is 2.5 meters long. Go to
This ends the procedure.HSL_IBThis is a 12X cable (green connectors).Go to HSL_LNK and follow the appropriate instructions.This ends the procedure.HSL
Failing function code 2533The Ethernet adapter might be failing.Use the following table to determine the part number for the field replaceable unit (F
Table 8. HSL_LNK service information (continued)FRU DescriptionINT_12X This is an internal 12X connection in an enclosure. Someunits have internal 12X
Table 9. 12X FRU parts (continued)CCIN or FFC Type and model Part number Description Location code2BBD 9117-MMB,9117-MMC,9117-MMD,9179-MHB,9179-MHC,91
Table 11. 12X FRU partsCCIN or FFC Type and model Part number Description Location code520A 5796, 7314-G30 See System parts. Riser Un-P1-C7520B 5796,
One end of the cable has an HSL/RIO yellow connector and the other end has an HSL2/RIO-G blackconnector. The "xx" value indicates the length
Reference codeType and model orfeature code Part number Description Location code3114 8408-E8D, 9109-RMD,9117-MMB,9117-MMC,9117-MMD,9179-MHB,9179-MHC,
v No: Continue with the next step.v Yes: Replace port card 2 in the 5802 expansion unit at location Un-P3-C2. If this is your secondtime here, replace
IH_HUBThe I/O hub might be the failing item.Replace the system backplane at location Un-P1.If you need additional information for failing part numbers
CCIN Description Type and model Part number73.4 GB 15,000 rpm ultra3SCSI disk drive and carrier03N634503N528073.4 GB 15,000 rpm ultra3SCSI disk drive
IO_HUBThe failing component is the RIO/HSL hub on the IPL path.Use the following table to determine the part number for the field replaceable unit (FR
3. Using the location codes you have identified, determine which system unit and expansion units havePCI adapters of this type assigned to the partiti
ESCALA Models Reference The ESCALA Power7 publications concern the following models: Bull Escala E1-700 / E3-700 (31E/2B ,8231-E2B) Bull Esc
* Designed to comply with RoHS requirement.** Not designed to comply with the RoHS requirement.If you need additional information for failing part num
Table 12. Failing items for symbolic FRU IOADPTR (continued)FRU name (replace FRUs in order,one at a time, starting with theprimary unit and then the
Table 12. Failing items for symbolic FRU IOADPTR (continued)FRU name (replace FRUs in order,one at a time, starting with theprimary unit and then the
Table 12. Failing items for symbolic FRU IOADPTR (continued)FRU name (replace FRUs in order,one at a time, starting with theprimary unit and then the
LBSADP1This symbolic FRU is not supported on the system.Continue with the next FRU in the failing item list.LBSADP2This symbolic FRU is not supported
v Yes: This ends the procedure.2. Is this the first time you are trying to update the server firmware while working on this problem?v No: Choose from
Attention: Be aware that a newer level of server firmware might already have been downloaded beforethis problem occurred or when the problem was repor
Have the customer check processor and memory allocations of the system or to the partition. Thecustomer must ensure that there are enough functioning
CCIN or FFC Type and model Part number Description Location code2BFB, 2BFC 8202-E4B, 8205-E6B,8231-E2BSee System parts. System backplane Un-P12B4B 820
Table 13. Multi-adapter bridge errorsProblem or message (these appear in uppercase in theconsole) Meaning or corrective actionMulti-adapter bridge has
Table 13. Multi-adapter bridge errors (continued)Problem or message (these appear in uppercase in theconsole) Meaning or corrective actionMulti-adapte
CCIN or FFC Type and model Part number Description Location code254E Any 13N2056 Fibre Channelexpansion cardIf you need additional information for fai
MASBUSThe multiadapter bridge detected a problem with a connection to a PCI adapter that it controls either in aphysical card location or embedded in
2. If the drive is a 6330 DVD-RAM, clean the drive. The part number for the DVD cleaning kit is19P0489.3. If it is a tape media, clean the recording h
CCIN or FFC Type and model Part number Description Location code8233-E8B, 8236-E8C See System parts. Processor card Un-P1-Cx8408-E8D, 9109-RMD,9117-MM
Feature Size2795/2895 128 MB2796/2896 256 MB2797/2897 1 GBNotes:1. At least 1 Pentium memory module is required in positions DIMM 0, DIMM 1, DIMM 2 or
This ends the procedure.MOVEIOAAn incorrect hardware configuration was detected.The I/O adapter used by a guest partition is on the same PCI bridge se
NODECRThere is a problem with the node controller in a 9119-FHB processor book.If you need additional information for failing part numbers, location c
NTDEVDRThe Windows server device driver might be causing the problem.Contact your next level of support for assistance.NTLANDDThe Windows server virtu
OPUSERThe failing item indicates that the operator of the system console or the control panel performed anincorrect action.For more information, see 3
2. Use the location code in the serviceable event view to find the location where the cable attaches to thesystem and then replace the cable.If you ne
PCIERE1Use this procedure to reseat the PCI Express (PCIe) cable and enclosure RAID module.Complete the following steps:1. Is a location code in the f
Failing function code 2556A 146 GB SAS interface 3.5 inch form-factor drive might be failing.Use the following table to determine the part number for
If you need additional information for failing part numbers, location codes, or removal and replacementprocedures, see Part locations and location cod
8408-E8D, 9109-RMD See System parts. Midplane Un-P19117-MMB, 9117-MMC, 9117-MMD, 9179-MHB, 9179-MHC, 9179-MHDCCIN or FFC Type and model Part number De
– Voltage regulators– BackplaneUse the following tables to determine the part number for the field replaceable unit (FRU).5796, 7314-G30CCIN or FFC Ty
PIOCARDThe hardware that controls PCI adapters and PCI card slots detected an error.If you need additional information for failing part numbers, locat
Table 15. Failing items for symbolic FRU PIOCARD (continued)2BFB, 2BFC 8202-E4B, 8205-E6B See description PCI adapter. If youhave detected afailing PC
Table 15. Failing items for symbolic FRU PIOCARD (continued)2B2C 8205-E6D, 8231-E2D See description PCI adapter. If youhave detected afailing PCI adap
Table 15. Failing items for symbolic FRU PIOCARD (continued)2BB9 9117-MMB,9179-MHBSee description PCI adapter. If youhave detected afailing PCI adapte
Table 15. Failing items for symbolic FRU PIOCARD (continued)520C 5796, 7314-G30 See description PCI adapter. If youhave detected afailing PCI adapter
PPCISYSThe failing component is the primary PCI bus in a system unit.Use symbolic FRU PRI_PCI to determine the FRUs and service information.This ends
If you need additional information for failing part numbers, location codes, or removal andreplacement procedures, see Part locations and location cod
If you need additional information for failing part numbers, location codes, or removal and replacementprocedures, see Part locations and location cod
Type and model Failing items9125-F2C1. Replace the DCCAs at locations Un-P1-C147 andUn-P1-C148, one at a time.2. Replace the system backplane at locat
CCIN or FFC Type and model Part number Description Location code1464, 6008 Any 22R5219 SPCN cable (6meters)1465, 6007 Any 22R5221 SPCN cable (15meters
1. Is the reference code 1xxx15xx 1xxx60x6, or 1xxx71xx?v No: Continue with the next step.v Yes: Complete the following steps:a. Find the unit referen
1510, 1511, 1512, 1513,1514, 71109117-MMB,9117-MMC,9117-MMD,9179-MHB,9179-MHC,9179-MHDSee System parts. Power supply Un-E11520, 1521, 1522, 1523,1524,
Reference code Missing power supply Service action1xxx1601 Un-E1 If the power supply is missing, installit. If the power supply is installed,ensure th
7. Is the reference code 1xxx3154 or 1xxx3155?v No: Return to Starting a repair action. This ends the procedure.v Yes: Replace the power supply (DCA)
Note: Serial numbers are case sensitive. (All alpha characters contained in the serial number must beentered as a capital letter.)v 8D for the 7314-G3
22. Return to the procedure that sent you here.QDCCRLSLicensed Internal Code is the failing item.Look for PTFs associated with the reference code and
ROUTERAny network switch that iSCSI data might pass through between the IBM i iSCSI target adapter and aSystem x or BladeCenter iSCSI initiator adapte
3. Is the device an internal device (not in an external expansion unit)?v No: Replace the expanders/ESMs in the external expansion unit one at a time
256D Any 26R089326R08894 Gb Fibre ChanneladapterIf you need additional information for failing part numbers, location codes, or removal and replacemen
SI_CARDThe failing component is the 12X adapter card in the system unit.Use the following table to determine the part number for the field replaceable
– IBM i Hardware Service Manager (HSM)– Hardware Service Manager (HSM)– The system configuration listingRecord the unit type or feature and continue w
2. Use the following table to find the replacement FRU part number for the FRU location identifiedpreviously in this procedure.CCIN Type and model Par
v Yes: Use that location and Table 25 on page 334 to find and replace the failing part. This ends theprocedure.v No: Continue with the next step. Note
b. Compare the values from the previous step to the loop location information table for your serverbelow. Record the values for the 12X loop number an
Table 23. 9117-MMC, 9117-MMD, 9179-MHC, or 9179-MHD SIIOADP 12X loop location informationHub (decimal) Loop number (hex / dec)Location code for leadin
5. Isolate the failing 12X adapter by walking the cabling for the specified 12X loop from the leading portto the trailing port. Complete the following
Table 25. SIIOADP FRU part numbers (continued)2BC3 8408-E8D, 9109-RMD,9117-MMB,9117-MMC,9117-MMD,9179-MHB,9179-MHC,9179-MHDSee System parts. 12X adapt
Table 26. Correcting an invalid configuration on an HSL/RIO loop (continued)PRC Problem identified Corrective actionxxxx 3201 Clustered systems on mul
Table 27. Status indicated by the PRC (continued)PRC Indicated status3205 During the IPL, Licensed Internal Code determined that the loop was not comp
2571 Any 80P4353 2-Port PCIAsynchronousEIA-232 adapterIf you need additional information for failing part numbers, location codes, or removal and repl
2. Is there a range of card positions (PCI bridge set) listed in the problem view for this failing item?v No: Continue with the next step.v Yes: Licen
v Yes: The first two characters in word 4 of the reference code will identify the platform LicensedInternal Code component that has control of the slo
FRU name (check in order, one at a time) Location8231-E2B, 8231-E1C, 8231-E1D, 8231-E2C, 8231-E2Dservice processor to management console Ethernet cabl
STGCARTThe USB removable storage cartridge might be failing.Complete the following steps:1. Is a location code available in the serviceable event view
Read the SRC description and perform any actions indicated.SVCPROCThe service processor might be failing.Use the table below to determine the FRU part
If you need additional information for failing part numbers, location codes, or removal and replacementprocedures, see Part locations and location cod
– If the first byte is a 50, replace the primary unit I/O backplane.– If the first byte is a 51, replace the secondary unit 1 I/O backplane.v If you h
TAPCNFGLook here for information about TAPCNFG symbolic FRU.One of the following configuration problems was detected:v Tape and disk devices are attac
8202-E4B, 8202-E4C,8202-E4D, 8205-E6B,8205-E6C, 8205-E6D,8231-E2B, 8231-E1C,8231-E1D, 8231-E2C,8231-E2D, 8233-E8B,8236-E8CSee System parts. System uni
2. Select Start a service tool > Hardware service manager > Logical hardware resources > High-speedlink (HSL) resources.3. Select Include non
Failing function code 2579The cryptographic coprocessor adapter battery is the failing item.Use the following table to determine the part number for t
2. Each line in that 12X loop represents a 12X adapter or controller. Find the first one with a "TrailingPort Status" of failed. Replace the
TPMD_OVThe thermal power management firmware has detected that the system is operating without powersupply redundancy.The maximum power limit for the
The SPCN card can be on either an adapter style card or integrated on the system backplane or an I/Obackplane in an attached I/O expansion unit.Comple
– For SRC 1xxx5001:- For models 9117-MMB, 9117-MMC, 9117-MMD, 9179-MHB, 9179-MHC, 9179-MHD, replace theservice processor card in the second drawer of
– For a model 8202-E4B, 8202-E4C, 8202-E4D, 8205-E6B, 8205-E6C, 8205-E6D, 8231-E2B, 8231-E1C,8231-E1D, 8231-E2C, 8231-E2D, 8233-E8B, 8236-E8C, contact
UC235The problem might be that the card (a resource) was removed from the card enclosure without updatingthe system configuration records.Note: If the
Local System.----------.||| | Remote System| | Local Modem Remote Modem or Controller| | .-----------. .-----------. .----------.| +----+ +------//---
|| |||| |||| ||’----------’ The problem is here.UJ6P3An error occurred in the Facsimile Support/400 licensed program.Please contact your next level of
UJA34A configuration parameter might be incorrect.To determine the configuration parameter that was identified as a possible problem, search for the e
To determine the configuration parameter that was identified as a possible problem, search for the errorin the service action log and display the fail
If you need additional information for failing part numbers, location codes, or removal and replacementprocedures, see Part locations and location cod
The configuration parameter that was identified as a possible problem can be verified by displaying theIDLC line description with the DSPLINID command
This ends the procedure.UJE31There might be a problem with the Token-Ring Network Manager program.Contact the token-ring administrator responsible for
The configuration parameter that was identified as a possible problem can be verified by displaying thelocal area network control unit description wit
UJE40The problem might be at the remote site or on the network media.Complete the following steps:1. Ask the remote site operator to verify the follow
This type of error message sometimes contains information about system performance. See the originalsystem message for cause and recovery information
determine the part number. Using the resource name logged with this error and hardware servicemanager, determine the physical location of the solid st
UNM32The licensed internal code of the communications I/O card cannot obtain a necessary resource because ofa heavy workload.This can be caused by too
3. Consult your local ISDN network provider or service representative for assistance in correcting theproblem.This ends the procedure.UNU02The problem
Some software problems can be temporarily solved by changing the configuration parameter, even if theoriginal value was correct. Report this problem t
UPLF5The session initiation attempt might have failed because of a route selection problem.The available nodes and transmission groups in the Advanced
If you need additional information for failing part numbers, location codes, or removal and replacementprocedures, see Part locations and location cod
CCIN or FCC Type and model Part number Description Location codeUPS Remote powercontroller (RPC)If you need additional information for failing part nu
3. Find the product activity log for the system reference code (SRC) by completing the following steps:a. Select System Service Tools (SST).If you can
USB_IOAThe USB I/O adapter (IOA) might be failing.Complete the following steps:1. Is the IOA location available in the service action log?Yes: Replace
7. Record the 2 hexadecimal digits that immediately follow the D7C1E3C8 digits. This is the logical USBport number.8. Use the following table to deter
v The cables are located near a source of electrical interference.v The cables are loose, damaged, or not correctly connected.UY1Z2This error might oc
VIOSLOGCorrect any serviceable events in the Virtual I/O Server (VIOS) logical partition that is hosting the I/Odevices that reported the problem. If
– 8202-E4B, 8202-E4C, 8202-E4D, 8205-E6B, 8205-E6C, 8205-E6D, 8231-E2B, 8231-E1C, 8231-E1D,8231-E2C, 8231-E2D: If the processor modules and memory DIM
Reference code Action1xxx8414 Replace processor module 2 at location Un-P1-C10. SeeSystem parts to determine the part number for the fieldreplaceable
Reference code Action1xxx8413 Replace the processor card at location Un-P3. See Systemparts to determine the part number for the fieldreplaceable unit
Reference code Action1xxx8423 Replace processor card 1. If this replacement does not fixthe problem, replace the midplane. See System parts todetermin
CCIN or FFC Type and model Part number Description Location code2592 Any 39J3522 Slimline IDE 8X/24XDVD-ROMIf you need additional information for fail
v Yes: The wrong service processor card is installed or the VPD is not correct. Replace the serviceprocessor card in the failing drawer. Use the follo
v Yes: Replace port card 4 at location Un-P3-C4 in the 5802 expansion unit. This ends theprocedure.v No: Return to Starting a service call and look fo
380
NoticesThis information was developed for products and services offered in the U.S.A.The manufacturer may not offer the products, services, or feature
This information is for planning purposes only. The information herein is subject to change before theproducts described become available.This informa
Class A NoticesThe following Class A statements apply to the IBM servers that contain the POWER7 processor and itsfeatures unless designated as electr
VCCI Statement - JapanThe following is a summary of the VCCI Japanese statement in the box above:This is a Class A product based on the standard of th
Electromagnetic Interference (EMI) Statement - TaiwanThe following is a summary of the EMI Taiwan statement above.Warning: This is a Class A product.
EN 55022 Klasse A Geräte müssen mit folgendem Warnhinweis versehen werden:"Warnung: Dieses ist eine Einrichtung der Klasse A. Diese Einrichtung k
This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used inaccordance with the instructions, may cause ha
The following copyright notice protects this book under Copyright laws which prohibit such actions as, but not limited to, copying, distributing, mo
CCIN or FFCType andmodel Part number Description Location code25A2 Any For 8202-E4B, 8202-E4C, 8202-E4D,8205-E6B, 8205-E6C, 8205-E6D, seeManaging devi
VCCI Statement - JapanJapanese Electronics and Information Technology Industries Association (JEITA)Confirmed Harmonics Guideline (products less than
Dieses Produkt entspricht den Schutzanforderungen der EU-Richtlinie 2004/108/EG zur Angleichung derRechtsvorschriften über die elektromagnetische Vert
IBM reserves the right to withdraw the permissions granted herein whenever, in its discretion, the use ofthe publications is detrimental to its intere
Printed in USA
CCIN or FFC Type and model Part number Description Location code25A4 Any See PCIe 2-portAsync EIA-232Adapter (FC 5289 andFC 5290).2-port PCIeasynchron
CCIN or FFC Type and model Part number Description Location code25C2 Any 00P4290 IBM dual-portGigabit SX EthernetPCI-X adapterIf you need additional i
If you need additional information for failing part numbers, location codes, or removal and replacementprocedures, see Part locations and location cod
Failing function code 25E6The graphics adapter might be failing.Use the following table to determine the part number for the field replaceable unit (F
If you need additional information for failing part numbers, location codes, or removal and replacementprocedures, see Part locations and location cod
Failing function code 2603The 1-port or 2-port 4 Gb PCIe Fibre Channel adapter might be failing.Use the following table to determine the part number f
Failing function code 2609The Fibre Channel adapter might be failing.Use the following table to determine the part number for the field-replaceable un
2612 Any 19P4898 80/160 GB internaltape drive with VXAtechnologyUn-Px-DxIf you need additional information for failing part numbers, location codes, o
Failing function code 2616The 36/72 GB 4 mm internal tape drive might be failing.Use the following table to determine the part number for the field re
ContentsSafety notices ...vFailing function codes, failing items, and symbolic FRUs ...1Failing function code
If you need additional information for failing part numbers, location codes, or removal and replacementprocedures, see Part locations and location cod
Any See Failing functioncode 2625.PCIe QDR hostchannel adapterIf you need additional information for failing part numbers, location codes, or removal
263 Any 10N6535 EIA-232 TerminalcableUn-P1-Cx-TyIf you need additional information for failing part numbers, location codes, or removal and replacemen
Failing function code 2642The 73.4 GB U3 10,000 rpm 80–pin SCSI disk drive might be failing.Use the following table to determine the part number for t
If you need additional information for failing part numbers, location codes, or removal and replacementprocedures, see Part locations and location cod
CCIN or FFC Type and model Part number Description Location code2649 03N5272 or 03N6337 300 GB 10,000 rpmultra320 SCSI diskdriveUn-Px-DxIf you need ad
Failing function code 2650Configuring iSCSI devices.If you need additional information for failing part numbers, location codes, or removal and replac
If you need additional information for failing part numbers, location codes, or removal and replacementprocedures, see Part locations and location cod
CCIN or FFC Type and model Part number Description Location code266 Any 59F3432 RJ-45 to DB-25converter cableUn-P1-Cx-TyIf you need additional informa
Failing function code 2670A 73 GB SAS interface small form factor 10,000 rpm disk drive might be failing.Use the following table to determine the part
iv
If you need additional information for failing part numbers, location codes, or removal and replacementprocedures, see Part locations and location cod
If you need additional information for failing part numbers, location codes, or removal and replacementprocedures, see Part locations and location cod
CCIN or FFC Type and model Part number Description Location code2699 Any See System parts. 600 GB SAS interfacesmall form factor10,000 rpm disk driveU
Failing function code 26D0The DAT 320 160 GB SAS tape drive might be failing.Use the following table to determine the part number for the field replac
If you need additional information for failing part numbers, location codes, or removal and replacementprocedures, see Part locations and location cod
Removable disk cartridges are supply items. To receive warranty service or to purchase additionalremovable disk cartridges in the United States and Ca
Failing function code 271The problem is an X.25 attachment cable.Use the following table to determine the part number for the field replaceable unit (
If you need additional information for failing part numbers, location codes, or removal and replacementprocedures, see Part locations and location cod
CCIN or FFC Type and model Part number Description Location code2723 Any 35P1060 LTO6 FC tape driveIf you need additional information for failing part
If you need additional information for failing part numbers, location codes, or removal and replacementprocedures, see Part locations and location cod
Safety noticesSafety notices may be printed throughout this guide:v DANGER notices call attention to a situation that is potentially lethal or extreme
Failing function code 2756A GX++ 2-port 10 Gb FCoE CNA SR optical adapter might be failing.Use the following table to determine the part number for th
Failing function code 279The PTC resistor has been tripped.Note: This problem is related to a SCSI single-ended adapter. See SCSI service hints in the
If you need additional information for failing part numbers, location codes, or removal and replacementprocedures, see Part locations and location cod
Failing function code 2C9The problem is in the PCI bus on the I/O backplane.Replace the I/O backplane.If you need additional information for failing p
Failing function code 2D05The battery pack for the internal SAS RAID enablement card might be failing.Use the following table to determine the part nu
If you need additional information for failing part numbers, location codes, or removal and replacementprocedures, see Part locations and location cod
2BC2 8408-E8D, 9109-RMD,9117-MMB,9117-MMC,9117-MMD,9179-MHB,9179-MHC,9179-MHDSee System parts. 175 MB cache RAIDand dual storage IOAenablement cardUn-
CCIN or FFC Type and model Part number Description Location code2BD9 8202-E4B, 8205-E6B See System parts. RAID and cachestorage controllerUn-P1-C192BD
If you need additional information for failing part numbers, location codes, or removal and replacementprocedures, see Part locations and location cod
Failing function code 2D25An embedded SAS adapter might be failing.All failing items listed in the following table for a specific type and model must
DANGERWhen working on or around the system, observe the following precautions:Electrical voltage and current from power, telephone, and communication
Failing function code 2D28The RAID and cache storage controller might be failing.Use the following table to determine the part number for the field re
If you need additional information for failing part numbers, location codes, or removal and replacementprocedures, see Part locations and location cod
Failing function code 2E02The 10 Gb Ethernet-LR PCIe adapter might be failing.Use the following table to determine the part number for the field repla
If you need additional information for failing part numbers, location codes, or removal and replacementprocedures, see Part locations and location cod
If you need additional information for failing part numbers, location codes, or removal and replacementprocedures, see Part locations and location cod
CCIN or FFC Type and model Part number Description Location code2E24 Any See PCIe2 LP 2x10GbFCoE 2x1GbE SFP+Adapter (FC EN0J;CCIN 2B93).PCIe2 2-port 1
Failing function code 2E31A 10 Gb twinaxial Ethernet PCIe adapter might be failing.Use the following table to determine the part number for the field
2B56 8408-E8D, 9109-RMD,9117-MMC,9117-MMD,9179-MHC, or9179-MHD00E0778 2x1Gband2x10Gb twinaxial Ethernetadapter2B57 8408-E8D, 9109-RMD,9117-MMC,9117-MM
If you need additional information for failing part numbers, location codes, or removal and replacementprocedures, see Part locations and location cod
CCIN or FFC Type and model Part number Description Location code2E57 Any See PCIe2 LP 2x10GbFCoE 2x1GbE SFP+Adapter (FC EN0J;CCIN 2B93).PCIe2 2-port 1
Observe the following precautions when working on or around your IT rack system:v Heavy equipment–personal injury or equipment damage might result if
If you need additional information for failing part numbers, location codes, or removal and replacementprocedures, see Part locations and location cod
If you need additional information for failing part numbers, location codes, or removal and replacementprocedures, see Part locations and location cod
To determine the FRU part number, go to the service information for the system on which you areworking.If you need additional information for failing
Failing function code 442The problem is a 9.1 GB ultra LVD SCSI disk drive.See the following table for the FRU part number.CCIN or FFC Type and model
Failing function code 447The problem is a PCI 64-bit Fibre Channel adapter.The FRU part number is 80P4384.If you need additional information for faili
Failing function code 541The problem is a 40 GB tape drive.See the following table for the FRU part number.CCIN or FFC Type and model Part number Desc
Note: The FRU part numbers are interchangeable. Order the FRU part number that matches the FRU partnumber you are replacing.If you need additional inf
Failing function code 601The problem is a 9.1 GB LVD 68-pin SCSI disk drive.See the following table for the FRU part number.CCIN or FFC Type and model
If you need additional information for failing part numbers, location codes, or removal and replacementprocedures, see Part locations and location cod